www.ConcreteThinker.com
![]()
![]() Albert Litvin and Harold W. Belliston, Portland Cement Association, Item Code RD066
Many building codes require minimum sound transmission loss values, expressed as sound transmission class (STC), of 45 to 50. Tests of sound transmission loss were made on 8-in.-thick (203-mm) concrete masonry walls and on 6- and 8-in.-thick (152- and 203-mm) cast concrete walls finished with materials intended to increase sound transmission loss. Using furring, acoustic insulation, and wallboard attachments, STC values up to 59 and 63 were obtained for the masonry and cast concrete walls, respectively. Selected STC values, reported by other investigators, for a variety of walls are included for reference.
![]() A.C.C. Warnock , National Reseach Council Canada, #IR-586, 32 pages
Available for free.
This report presents the results of a series of sound transmission loss measurements carried out under contract for the Ontario Concrete Block Association. The test series was augmented for research purposes by measuring sound transmission losses at different stages in the construction and disassembly of the walls. The report that follows provides an analysis of the information obtained during the complete measurement series. Available as a free download at National Research Council of Canada's Institute for Research in Construction website.
|